FREJA 306 Standalone: Includes: International power cord, IEC 61850 test capability,
Transducer test capability, and test leads.
FREJA 306 Standalone: Includes: International power cord, with IEC 61850 test capability,
and test leads. Excludes: No transducer test capability
FREJA 306 Standalone: Includes: International power cord, Transducer test capability,
and test leads. Excludes: no IEC 61850 test capability
FREJA 306 Standalone: Includes: International power cord, and test leads. Excludes: no IEC
61850 test capability, no transducer test capability
FREJA 306 Standalone: Includes: International power cord and Transducer test capability.
Excludes: no IEC 61850 test capability, no test leads
FREJA 306 Standalone: Includes: International power cord, with IEC 61850 test capability.
Excludes: No transducer test capability, no test leads
FREJA 306 Standalone: Includes: International power cord. Excludes: no IEC 61850 test
capability, no transducer test capability, no test leads
Included Software – Every unit comes with the PC version of the
FREJA Local software called FREJA Remote.
订购信息
Description
Style Number
F306-30P2C1I1T1
F306-30P2C1I1S1
F306-30P2C1I0T1
F306-30P2C1I0S1
F306-30P2C1I0T0
F306-30P2C1I1S0
F5306-30P2C1I0S0
84835
Optional Software
84673
FREJA Win
Included Standard Accessories
Power Cord - Depending on the style number, the unit will come with one of the following,
Line cord, NEMA
90015-267
Line cord, Continental Europe with CEE 7/7 Schuko Plug
90015-268
Line cord, International color coded wire
90015-269
Line cord, United Kingdom
90015-270
Ethernet cable for interconnection to PC, 210cm (7 ft.) long (Qty. 1 ea.)
90003-594
Instruction manual (digital copy)
84624
产品规格 FREJA 306 | |
在30分钟的预热时间后,规格适用于电阻负载,额定电压供应和环境温度+ 25°C±3°C(77°F±5.4°F)。 所有硬件数据均为满量程值。规格如有更改,恕不另行通知。 | |
环境 | |
应用领域 | 用于高压变电站和工业环境。 |
温度 操作 储存和运输 湿度 |
0°C to +50°C (32°F to +122°F) -40°C to +70°C (-40°F to +158°F) 5% – 95% RH, non-condensing |
海拔高度 |
3000 m 全职周期可达2000米。 基于海拔大于2000米的内部过温保护的占空比限制。 |
CE-marking | |
EMC LVD |
2004/108/EC 2006/95/EC |
General | |
主输入(标称) | 100 – 240 V AC, 50 – 60 Hz |
能量消耗 | 1200 VA + 1500 VA (max) |
尺寸 |
仪器 450 x 224 x 410 mm(17.7” x 8.8” x 16.1“) 运输箱 610 x 345 x 660 mm(24” x 13.6” x 26”) |
重量 |
仪器 23 kg (50.7 lbs) 运输箱 12 kg (26.4 lbs) |
显示 | LCD |
可用语言 | English, French, German, Spanish,Swedish |
测量部分 | |
二进制输入 | |
编号类型 | 10 Inputs (2 groups of 5 indepen-dent)干或湿接触275 V DC,240 VAC响应时间补偿 |
内部解析时间 | 50 µs |
电隔离 | 与放大器部分电隔离。 两个电气分离的组:1至5和6至10 |
最大测试时间 | 15264 h (636 days) |
范围 | 分辨率 |
0 - 9.9 ms | 0.1 ms |
10 ms - 60 min | 1 ms |
1 h - 15264 h | 1 s |
直流电流输入, 低电平 | |
测试范围 | ±20 mA |
分辨率 |
SW 0.1 µA HW 0.6 µA |
不确定度 | 0.01% typical,0.03% guaranteed (= 6 µA) |
直流电压输入,低电平 | |
测试范围 | ±10 V |
分辨率 |
SW 0.1 mV= HW 0.3 mV |
不确定度 |
0.01% typical, 0.03% guaranteed (= 3 mV) |
AC /DC输入电流测量,高电平 | |
测试范围 | ±14 A DC, 10 A AC RMS |
不确定度 | DC <0.1%, AC <0.3% |
AC /DC输入电流测量,高电平 | |
测试范围 | ±220 V DC, 150 V AC RMS |
不确定度 | DC <0.05%, AC <0.2% |
测量,内部生成值 | |
不确定度 电压 AC / DC 电流 AC / DC |
<1% ±1digit <2% ±2digit |
进制输出 |
|
数字类型 | 2 x 4 (NO & NC)零电位触点,受控软件 |
断电容量 AC | 240 V AC, max 8 A, max load 2000 VA |
打破能力 DC | 275 V DC, max 8 A, max load 240 W |
低电平输出(Rogowski option) | |
设定范围 LLU LLI |
3 X 0...2 V RMS 3 X 0...2 V RMS |
最大输出电流 | 5 mA |
不准确的决议 | <0.1% typ. (<0.2% guaranteed) |
失真 (THD+N)2) Max. | 250 μV |
产生时间 |
<0.05% typ. (<0.1% guaranteed) 5 minutes |
发电机部分 | |
电压输出 | |
范围 4- 相 AC 1- 相 AC (L-L) DC(L-N) |
4 x 150 V 2 x 300 V 180 V |
功率 3- 相 AC 1- 相 AC (L-L) DC(L-N) |
3 x 82 VA at 150 V 1 x 140 VA at 300 V 87 W |
分辨率 SW HW |
10 mV 6.5 mV |
不确定度 3) ( 保证 ) | (±0.01% of range) + (±0.05% of reading) |
失真 (THD+N)4) | 0.02% typical (0.04% max) |
电流输出 | |
标准输出 – L1I, L2I, L3I | |
范围 3- 相 AC 1- 相 AC 2) DC(L-N) 3-通道DC |
3 x 15 A 1 x 45 A 15 A - |
功率 3- 相 AC 1- 相 AC 2) DC(L-N) |
3 x 87 VA 1 x 250 VA 3 x 87 W(max) |
分辨率 SW HW |
1 mA 0.65 mA |
不确定度 3) ( 保证 ) | (±0.01% of range) + (±0.3% of reading) |
失真 (THD+N)4) | 0.1% typical (0.2% max) |
中断输出 – Ch1, Ch2, Ch3 | |
电压瞬变 - | 抗扰度 2500 V 瞬态水平(to chassis) +工作电压等级(255 V) |
工作电压 | 255 V |
应用 | |
3- 相 AC( 每相 ) |
250 VA, 5 A < I ≤ 25 A 200 VA, 25 A < I ≤ 30 A 150 VA, 30 A < I ≤ 35 A |
1- 相 AC (3 ch. in parallel) |
750 VA, 15 A < I ≤ 75 A 600 VA, 75 A < I ≤ 90 A 450 VA, 90 A < I ≤ 100 A |
3-ch. DC 合规电 | 3 x ±20 A |
压时间限制 | ≤50 Vrms |
连续 | 3 x 20 A, 150 VA (max) |
0.5 秒在 1 秒内反复熄灭 | 3 x 35 A |
分辨率 | 1.6 mA |
典型不确定度 |
< 0.3% (of reading), 0.5 A < I ≤ 35 A < 8 mA, 0 A < I ≤0.5 A |
相不确定度 | < ±0.2° |
失真 (THD+N) 6) | < 0.4% typical |
发电机,一般 | |
频率范围 |
|
连续信号 | DC – 2000 Hz |
瞬态信号 | DC – 3.5 kHz |
频率分辨率 | 1 mHz |
频率不确定度 | 0.01% |
相角范围 | 0 – 360° |
相位分辨率 | 0.1° |
相位不确定度 | ±0.1° |
连接(放大器输出) | 4 mm可堆叠安全插头或8针放大器多功能插孔 |
所有七台发电机在振幅和相位上均可连续独立调节。不需要切换范围。 所有的电流和电压输出都是完全过载和短路保护,可以防止外部高压瞬态信号和过热。 | |
注意 允许连续生成高直流电流(12-15 A),需要0.2欧姆的最小负载阻抗。 对于较低的负载阻抗,例如 短路时间限制在1分钟。 | |
直流辅助电压输出 | |
范围 | 20 – 210 V DC |
输出功率 | 75 W at 210 V |
MEGGER FREJA 306继电器测试系统说明文档 |